DSM/SCM Messages Manual
DSM/SCM EMS Messages
DSM/SCM Messages Manual—529845-006
5-67
3070
3070
DSV-name
is the name of a distribution subvolume (DSV) in the software input.
Cause. The format of the A1CINFO file in this DSV is not readable by this DSM/SCM
PVU. Information included in the A1CINFO file might cause the format of the file to
change in the future.
Effect. The receive software request stops in a restartable state.
Recovery. Cancel the receive software request. Upgrade to the latest DSM/SCM PVU
and restart the request.
3071
DSV-name
is the name of a distribution subvolume (DSV) in the software input where the error
occurred.
Cause. The software being received contains a new version of the A7CINFO file that
the current DSM/SCM PVU cannot read.
Effect. The receive software request stops in a restartable state.
Recovery. Cancel the receive software request. Upgrade to the latest DSM/SCM PVU
and restart the request.
The DSV
DSV-name
has an A1CINFO file with an unknown file
format version. A more recent version of DSM/SCM is required
to receive this software.
The DSV
DSV-name
has an A7CINFO file with an unknown file
format version. A more recent version of DSM/SCM is required
to receive this software.