DSM/SCM Messages Manual
DSM/SCM EMS Messages
DSM/SCM Messages Manual—529845-006
5-129
5190
5190
subvolume-name
is the name of the SYS
nn
subvolume related to the current configuration.
target-name
is the name of the logical target.
system-volume
is the name of the system volume where the SYS
nn
subvolume was expected to
reside.
Cause. The physical system volume was lost, or the specified logical target was
deleted.
Effect. DSM/SCM deletes the logical target from the target system.
Recovery. If you are deleting a logical target, this is an informational message only;
no corrective action is needed.
If the logical target was unintentionally deleted, perform another Build/Apply request for
the same configuration.
If the message is caused by a corrupted disk, install a new disk with the same name as
the old disk; then perform another Build/Apply request for the same configuration.
The SYSnn
subvolume-name
for the current configuration of
target
target-name
is missing from
system-volume
and was not
found anywhere else on the system. The target
target-name
is
being deleted from the target system.
The DSM/SCM database will be updated accordingly.