DSM/SCM Messages Manual

ZPHIRNM Messages
DSM/SCM Messages Manual529845-006
4-3
Termination Messages
Cause. A flag in the ZPHISYS file indicates that an Apply is in progress. You should
not run ZPHIRNM during an Apply.
Effect. ZPHIRNM prompts you to override this error, to exit ZPHIRNM, or to request
more information. (The default is to exit.)
Recovery. Use the Target Interface to determine the status of the Apply. If an Apply is
in progress, run ZPHIRNM only after the Apply finishes or is cancelled. If an Apply is
not in progress, you can override this flag and continue running ZPHIRNM.
Cause. ZPHIRNM determined that processing has already completed for this SYS
nn
.
This determination is based on the SYSTEM.ZPHISYS file on the same volume as the
SYS
nn
, which indicates:
The SYS
nn
is the same as the last SYS
nn
renamed to.
The Last Modification Times (LMT) of SYS
nn
.OSIMAGE and SYS
nn
.ZSSLIST
have not changed since the last time ZPHIRNM ran.
The rename status for the configuration is RENAME FINISHED.
Effect. ZPHIRNM prompts you to override this error, to exit ZPHIRNM, or to request
more information. (The default is to exit.)
Recovery. To continue to run ZPHIRNM anyway, override this message. Otherwise,
exit ZPHIRNM.
** E01/E02 ZPHIRNM has detected that an APPLY activity is in
progress for this system (according to a flag in
filename
).
ZPHIRNM should not be run while an APPLY is in
progress.
O - Override, E - Exit, ? - More info [E]:
** E03/E04 ZPHIRNM for
filename
has already finished
processing.
O - Override, E - Exit, ? - More info [E]: