DSM/SCM User's Guide
Activating New Software on a Target System
DSM/SCM User’s Guide — 529846-014
10 - 2
Summary of Activating the Software
Summary of Activating the Software
The operator instructions are transferred to the target system in the activation package. 
Most activities performed outside of DSM/SCM that are mentioned in your operator 
instructions are not documented in detail here because these procedures can change 
for different RVUs. For more information, you are referred to other manuals as 
appropriate.
1. Some major updates require additional migration steps, so first check the release 
documentation for each RVU you install. (Interactive Upgrade Guide 2, Gxx.xx 
Software Installation and Upgrade Guide, and Hxx.xx Software Installation and 
Upgrade Guide.) 
2. Review the operator instructions for activating the new software on the target 
system. If you performed the Apply separate from the Build, you should already 
have the operator instructions. If not, proceed to Print the Instructions for Activating 
the Software on page 10-3.
3. Perform the operator instructions. 
Activate Software on the Target 
___ Run the ZPHITI. > RUN ZPHITI
___ Log on to the ZPHITI. Enter an authorized user 
and p
assword, p
ress F1
___ Select Perform target 
activities. Enter 3, press F1
___ Find and enter the number corresponding to the logical 
target on
 which to apply the software.
Enter target number, 
press F1
___ View operator instructions and follow them. Enter 3, press F1
___ Exit the ZPHITI. Shift-F16
___ Run ZPHRNM in PREVIEW mode:
> RUN ZPHRNM SYSnn , 
PREVIEW 
nn is the numbe
r of the 
SYSnn
 you just created.
___ Do you want to use a log file? Yes
___ Enter a file name. For example: $system.target.rnmlog1 $system.subvol.file
___ When finished, correct errors and run ZPHIRNM:
> RUN ZPHRNM SYSnn
SYS01
___ After ZPHIRNM successfully completes, boot up from the 
new SYSnn using OSM. 
SYS01