DSM/SCM User's Guide
Troubleshooting
DSM/SCM User’s Guide — 529846-014
13 - 13
Build/Apply Troubleshooting
Build/Apply Troubleshooting 
Problem Recovery 
A Build error occurs indicating 
unprocessed A7CINFO files.
OSS software was received into the 
Archive with a pre-D46 DSM/SCM PVU, 
resulting in unprocessed A7CINFO files.
Receive the OSS software into the Archive 
again with the Receive All Files option, 
using a D46 or later DSM/SCM PVU.
An Apply request stops in a 
restartable state with a message that 
an expected fingerprint was not found 
or with an error 179.
Apply looks for files belonging to the 
previous configuration revision before 
placing files for a new configuration revision 
if the files have not changed between 
revisions.
Although the Apply can be restarted if you 
find the right version of the file and put it in 
the right place, the more usual recovery is 
to:
Cancel the Apply from the ZPHITI.
Perform a Verify Database.
Create an Independent Snapshot.
Verify that the snapshot is received on the 
host using the Planner Interface.
Create a new revision based on the current 
configuration revision (with no changes), 
and resubmit the Build/Apply.
DSM/SCM requires that two revisions of 
the configuration be on the t
arget system. 
DSM/SCM refers to these two revisions as 
Saved Previous and Current. Because 
DSM/SCM sends only changed files to the 
target system as the default, it depends on 
the correct files for these two revisions 
being on the target. Each time an Apply is 
initiated, DSM/SCM checks to ensure that 
the files it did not send (because they did 
not change) still exist. (This check is not 
done for data files.) Because a file might be 
under its actual name or its temporary 
name, DSM/SCM checks the existence and 
attributes of the actual file name and the 
corresponding ZFBnnnnn name.