DSM/SCM User's Guide
Troubleshooting
DSM/SCM User’s Guide — 529846-014
13 - 15
Build/Apply Troubleshooting
During a Build, an Object Manager 
error communicating with SWID 
occurs.
The specified CONFTEXT file has either 
been deleted, renamed, or secured so that 
DSM/SCM cannot read it.
When a Build/Apply dialog box is opened, 
DSM/SCM runs SWID to determine 
whether the CONFTEXT file has changed 
and a system generation is therefore 
required.
This error might also indicate a SWID error 
such as unresolved externals.
During a Build request, a message 
indicates that the release is not 
supported, or that the RVU is not 
supported.
The software revision was not based 
initially on an RVU.
Create a new revision, then do one of:
Select an RVU to copy to the configuration 
revision.
Select the T6032 product for the site ID to 
copy. The Planner Interface shows the RVU 
selected.
The RVU of a configuration revision is 
needed in order to choose the correct tools 
for building the configuration (the correct 
system generation program and correct 
version of tools a system generation 
program runs). This release level is 
obtained when an RVU is selected from the 
Software in Archive window and a Copy to 
a revision is performed. This RVU is not 
changed if you select List Products on 
Software in Archive inputs and then select 
products to copy to the new revision.