DSM/Tape Catalog Management Programming Manual
Errors
DSM/Tape Catalog Management Programming Manual—520481-003
A-15
609 ZMCS-ERR-NOTONLYVERSION
609 ZMCS-ERR-NOTONLYVERSION
An attempt to alter a tape file to valid status failed because a valid version of that
generation already exists.
Cause. You are attempting to alter a version of a tape file to valid status, but a valid
version of that generation already exists.
Effect. No change is made.
Recovery. To make this version of the generation valid, you must delete the current
valid version.
610 ZMCS-ERR-VOLUMENOTALTERED
A tape volume could not be altered because of a reported error.
Cause. Due to an error, you cannot alter the entry for the tape.
Effect. The command does not execute.
Recovery. Analyze the error.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST
Corresponding MEDIACOM Error Message
Unable to alter the tape file because a valid version of that
generation already exists.
ZSPI-TKN-ERRLIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZMCS-TKN-TAPEVOLUME token-type ZSPI-TYP-STRING
ZMCS-TKN-POOLNAME token-type ZSPI-TYP-STRING
ZMCS-TKN-VOLUMECATALOG token-type ZSPI-TYP-STRING
ZMCS-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYPE-ERROR
.Z-SSID type ZSPI-DDL-SSID
.Z-ERROR type ZSPI-DDL-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ENDLIST
Corresponding MEDIACOM Error Message
Unable to alter the tape volume name1 of pool name2 from the
volume catalog name3 because of the following error: