DSM/Tape Catalog Management Programming Manual
Errors
DSM/Tape Catalog Management Programming Manual—520481-003
A-120
6027 ZMCS-ERR-TAPEVOLUMEEXISTS
6027 ZMCS-ERR-TAPEVOLUMEEXISTS
A tape with a name you specified is already cataloged in DSM/TC.  
Cause. A tape with a name you specified is already cataloged in DSM/TC.
Effect. By default, you cannot create two tapes with the same name.
Recovery. If you want two tapes with the same name, use the OVERRIDE option 
(with caution). For more information, see the ADD TAPELABEL command in the 
DSM/Tape Catalog Operator Interface (MEDIACOM) Manual.
6028 ZMCS-ERR-OUTTERMWRITE
A file-system error was returned while trying to write to the OUT file.  
Cause. A file-system error was returned while trying to write to the out-file.
Effect. The command does not execute.
Recovery. Analyze the file-system error. For descriptions of file-system errors, see the 
Guardian Procedure Errors and Messages Manual.
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST
Corresponding MEDIACOM Error Message
A tape with that name is already cataloged. Use the OVERRIDE 
option to allow the creation of a duplicate named tape volume 
outside DSM/TC control.
ZSPI-TKN-ERRLIST
 ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
 ZMCS-TKN-ERRORNUM token-type ZSPI-TYP-INT
ZSPI-TKN-ENDLIST
Corresponding MEDIACOM Error Message
File system error, error-number, occurred on the WRITE to the 
out-file.