DSM/Tape Catalog Management Programming Manual

SSI Event Messages
DSM/Tape Catalog Management Programming Manual520481-003
C-38
4 ZSSI-EVT-FATAL-FAULT,
zssi-val-msg-SEND-NI-FAIL (32)
4 ZSSI-EVT-FATAL-FAULT, zssi-val-msg-SEND-NI-FAIL (32)
The communications mechanism of the Network Interface (NI) cannot accept a
message from the SSI.
ZSSI-TKN-ADDRESS
contains the remote TCP/IP address.
ZSSI-TKN-PORT
contains the port number.
Cause. The communications mechanism of the Network Interface (NI) cannot accept
a message from the $ZSSI.
Effect. $ZSSI terminates.
Recovery. Depending on the errors found in the message log, reestablish
communication with the NonStop Kernel portmapper and RPC. For more information,
see Remote Procedure Call (RPC) Facility and running the portmapper in the
DSM/Tape Catalog User’s Guide. If the error recurs, contact your support
representative and provide all relevant information:
Descriptions of the problem and accompanying symptoms
Details of the messages generated
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and a CPU dump, if applicable
If your local operating procedures require contacting the Global Customer Support
Center (GCSC), supply your system number and the numbers and versions of all
related products as well.
Tokens in Event Message
ZSSI-TKN-PROC-CALLER token-type ZSPI-TYP-STRING.
ZSSI-TKN-MSG token-type ZSSI-TYP-MSG.
ZSSI-TKN-STAT token-type ZSSI-TYP-STAT
ZSSI-TKN-PROC-FAILED token-type ZSPI-TYP-STRING
ZSSI-TKN-ADDRESS <1> token-type ZRPC-TYP-IP-ADDR.
ZSSI-TKN-PORT <2> token-type ZSPI-TYP-INT.
Message Text
Cannot send message to NI: discarded, Address: <1>, Port: <2>