DSM/Tape Catalog Messages Manual
Tape Server Process Messages
DSM/Tape Catalog Messages Manual — 422947-007
11 - 4
Tape Server Process EMS Message Text
volser1
volser2
are the tape label names.
Cause. $ZSVR detected a mismatched tape mounted by the StorageTek ACS.
Effect. The application receives file-system error 595, and the tape volume is ejected
from the StorageTek ACS. For more information on this error, see Section 13, File-
System OPEN Errors.
Recovery. Label the tape correctly, or use a different tape volume and retry the
application.
volser
is the tape volume name.
Cause. $ZSVR could not dismount a tape from a tape drive in the StorageTek ACS.
For more information, see the EMS log.
Effect. The tape volume might still be loaded on the tape drive.
Recovery. Check to verify that the tape volume was unloaded from the tape drive.
drive
is the tape drive name.
Cause. $ZSVR detected a mismatched tape type mounted by the StorageTek ACS.
Effect. The application receives file-system error 595, and the tape volume is
dismounted from the StorageTek ACS. (The name of the tape was correct, but the
LABEL attribute was mismatched.) For more information on this error, see Section 13,
File-System OPEN Errors.
Recovery. Label the tape correctly, or use a different tape volume and retry the
application.
Error 1014 - Ejecting mismatched tape, internal: volser1,
external volser2
Error 1015 - Dismount of ACS tape, volser, failed
Error 1016 - ACS tape mounted on drive, drive, wrong label
type