DSM/Tape Catalog Messages Manual

MEDIASRV Syntax and Content Error Messages
DSM/Tape Catalog Messages Manual 422947-007
4 - 6
Error Numbers 5001 Through 6000
5022
Cause. An attempt was made to reset the COUNT option.
Effect. The command does not execute.
Recovery. Do not attempt to reset the COUNT option.
5023
Cause. The number of tapes specified with the COUNT option exceeds the number of
tapes specified in the tape-name part of the LABEL TAPEVOLUME command. For
example, the name of the tape chosen was ABCDE0, with a COUNT of 50. ABCDE0
accommodates only up to 10 tapes (0 through 9).
Effect. The command does not execute.
Recovery. Make sure the tape-name you specify can actually generate as many
tape names as you specify with the COUNT option.
5024
Cause. An invalid TIME value was specified.
Effect. The command does not execute.
Recovery. Specify a valid TIME value.
5025
Cause. The DENSITY value was not specified as 1600 or 6250.
Effect. The command does not execute.
Recovery. Specify either 1600 or 6250 for the DENSITY value.
**ERROR-5022** COUNT cannot be reset.
**ERROR-5023** COUNT exceeded maximum for the TAPEVOLUME
specified.
**ERROR-5024** TIME is invalid.
**ERROR-5025** DENSITY must be 1600 or 6250.