EM3270 Manual
Event Management Service
Tandem EM3270 Manual—110332 J-11
7: ZEM3-EVT-NO-BUFFERS
Probable Cause
This could indicate a logic error in the MBCS handling of EM3270.
Recommended Action
Report the failure with a TPR (Tandem product report).
7: ZEM3-EVT-NO-BUFFERS
During the startup of a new terminal task, buffer space was not available. The task will
not be started.
Probable Cause
Insufficient buffer space due to configuration or to dynamic system resource problems.
Recommended Action
Check the DATAPAGES process parameter and adjust as necessary. If DATAPAGES is
set to zero indicating dynamic allocation, check the available free space on the disk used
for this purpose.
Event-Message Text
<1>: MBCS conversion error: <2> task #<3>
Unconditional Tokens Token Type
ZEMS-TKN-EVENTNUMBER ZEM3-EVT-NO-BUFFERS
ZEMS-TKN-SUBJECT-MARK
ZCOM-TKN-SUBJ-PROC <1> process-name
ZEMS-TKN-EMPHASIS ZSPI-VAL-FALSE
ZEMS-TKN-CONSOLE-PRINT ZSPI-VAL-TRUE
ZEM3-TKN-TASKID <2> task-number
Event-Message Text
<1>: Buffers not available to start task #<2>