EM3270 Manual
EM3270 Emulator Command Set
Tandem EM3270 Manual—110332 4-23
SET Command
LOGMODE text
a name, one to eight characters in length, enclosed in quotation marks which
identifies a logmode table residing in the SNA host. This parameter is optional.
Messages: 1008, 1040, and 1041.
STARTFF { ON | OFF }
specifies whether a form feed is issued at the start of a printer session file. The form
feed, if specified, is delayed until the arrival of the first print data. For CRT
sessions, STARTFF specifies whether a form feed is issued before a screen print
operation. The default value for STARTFF is ON.
Messages: 1004, 1008, and 1015.
TIMEOUT time
specifies the time in seconds the EM3270 emulator will use to establish the logical
end of a print file from the IBM host. TIMEOUT can be specified for each printer
to be configured. If no further data is received for the period specified by the time
parameter, the EM3270 emulator closes the spooler output file and reopens a new
file. If the value of time is zero, the EM3270 emulator does not timeout. Only
values in the range from 0 through 32767 are valid. The TIMEOUT specification
has meaning only when DEVTYPE is set to PRINTER. You can use TIMEOUT
separately or with EOFTEXT. The default is 3600 seconds (1 hour).
Messages: 1001, 1008, and 1042.
TRACFILE file-name
specifies the file name to be used when the diagnostic trace is enabled using the
TRACE command. If a disk file name is specified, the last two digits of the name
are replaced by the last two digits of the task number.
Messages: 1008, 1014, and 1039.
The parameter-spec for a PROCESS object is shown below. You must specify one of
the following parameters:
ADVISORY text
AUTORESTART { ON | OFF }
CPUS cpu-number [ :cpu-number ]
DATAPAGES number
LIBRARY file-name
LIKE process-name
LOG1 file-name
LOG2 file-name
LOGOPENS { ON | OFF }
MODEMERR { ON | OFF }
NOTIFY { ON | OFF }
NUMLOCK { ON | OFF }
PRI priority
PROCID process-name
PROGRAM file-name