EMS FastStart Manual

EMS FastStart Messages
EMS FastStart Manual133701
A-6
** Warning 70 ** The FIELD-<field-number>-TYPE parameter was not
validated.
Probable cause:
EMS FastStart was not able to validate this field data type since it is
not one of the default data type supported. The supported data type are
described in the EMS FastStart manual.
Recommended action:
If this data type was added in the EXTRADDL file, then you can ignore this
warning. You should assure that this type is declared as a character
field,since EMS FastStart does not support structures.
** Error 71 ** The FIELD-<field-number>-NUMBER parameter is invalid.
Probable cause:
It must be between 0 and 9990. The field numbers 9991 through 9998 are
reserved for EGEN.
Recommended action:
Please correct the FIELD-<field-number>-NUMBER in the ACF.
** Error 72 ** Duplicated FIELD-<field-number>-NUMBER parameter.
Probable cause:
The FIELD-<field-number>-NUMBER parameter was already used by another
field.
Recommended action:
Please correct the FIELD-<field-number>-NUMBER in the ACF.
** Error 73 ** EMS FastStart internal error.
Probable cause:
This is an internal error that occurred when trying to validate the ACF
parameters. It should never occur unless there is an integrity problem
within the routine Utils:parse^acf^file.
Recommended action:
Please submit the problem to Tandem with the following files: EMSFS,
EMSFSC20,CCF, EXTRADDL, and your ACF.