EMS FastStart Manual
Running EMS FastStart
EMS FastStart Manual–133701
5-4
Running EMS FastStart–ATM Example
Running EMS FastStart–ATM Example
This section shows you how to generate a sample run of EMS FastStart using the default
ACF called SATMACF.
Following the command entries, a listing of what you will see on your screen is shown.
In order to clarify the process, the listing is divided into steps which are grouped as
follows:
Parameter Validation (Steps 1-2)
Cleaning the Subvolume (Step 3)
Source File Generation (Steps 4 - 8)
Automatic Compilation (Steps 9 - 13)
File Creation: ATM1TEST and ATM1INDX (Steps 14 - 16)
Note that the EMS FastStart run will stop if an error occurs. You will receive an error
message advising you of the probable cause and the recommended action (listed and
described in detail in Appendix A, EMS FastStart Messages
. Correct the error and run
the program again.
Here is a sample EMS FastStart run:
Enter the GENERATE acf-filename command to start an EMS FastStart session.
The EMS FastStart response following the RUN and GENERATE commands is shown
below as it will appear on your screen.
Parameter Validation (Steps 1-2)
Steps 1 and 2 show the validation of the ACF and CCF parameters.
STEP #1: Reading and validating the ACF: $DATA.ZEMSFS.SATMACF.
--------------------------------------------------------------------------
--
-- EMS FastStart - T9263C20 - (17MAR91)
--
-- File Type: ACF
--
-- File Version: B00
--
-- Creation Date: September 17, 1989 10:54:31
TACL> volume $data.zemsfs
TACL> run emsfs
EMS FastStart - T9263C20 - (17MAR91)
Copyright Tandem Computers Incorporated 1989,1990,1991
** Comment 1 ** EMS FastStart set up completed.
TACL> generate satmacf
EMS FastStart - T9263C20 - (17MAR91)
, Operating System C20, System name \MTL
October 15, 1989 22:24:28