EMS FastStart Manual

Testing Program and Filter
EMS FastStart Manual133701
7-3
Testing Program Sample Session
>D
Please enter the required information:
ssid owner (ZSPI-TYP-CHAR8): CUSTOMER
ssid subsystem number (ZSPI-TYP-INT): 1
ssid version (ZSPI-TYP-UINT): 12345
event type (I,AA,AC,C): AA
action identifier (ZSPI-TYP-INT): 2
suppress-display (T,F): F
event number (ZSPI-TYP-INT): 100
subsystem manager (ZSPI-DDL-FNAME32):
event text (ZSPI-TYP-CHAR254): This is a test event generated by ATM1PROG
atm-name (ZSPI-TYP-CHAR8): MTL0122
atm-location (ZSPI-TYP-CHAR24): 221 Rene Levesque, MTL.
atm-account-num (ZSPI-TYP-INT2): 122345
atm-retry-limit (ZSPI-TYP-INT): 3
atm-hw-component (ZSPI-TYP-CHAR24):
atm-hw-subcomponent (ZSPI-TYP-CHAR24:
atm-serial-number (ZSPI-TYP-INT2): 334356
atm-sense-status (ZSPI-TYP-INT2): 03303
Please enter the name of the field which value will be the subject
of this event (e.g. Program-name, Atm-name, ...)
Event subject field name (ZSPI-TYP-CHAR24): atm-name
This is the current setting of EGEN-RECORD
Ssid owner: CUSTOMER
Ssid subsystem number: 00001
Ssid version: 12345
event type: Action-attention event
action-identifier: 2
suppress display: False
event number: 00100
subsystem manager name:
Event subject field name: atm-name
Event text: This is a test event generated by ATM1PROG
atm-name: MTL0122
atm-location: 221 Rene Levesque, MTL
atm-account-num: 0000122345
atm-retry-limit: 00003
atm-hw-component:
atm-hw-subcomponent:
atm-serial-number: 0000334356
atm-sense-status: 0000003303
EGEN generated the event message successfully
>H
This program will prompt you for the type of Event Message
to generate
The following event messages type are currently supported
I- Informative Event
AA- Action Attention Event
AC- Action Completion Event
C- Critical Event
D- Data entry event.. you enter the event fields
H- Help
E- Exit Program
>E
Example 7-1. Testing Program Sample Session (page 2 of 2)