EMS Manual

Filter Tables and Burst Filters
EMS Manual426909-005
6-5
Filter Table Errors
Filter Table Errors
These errors can be returned when the conversion from filter table text file to filter table
object fails. The return code for these errors is ZEMS-ERR-FLT-FORM (1019). The
detailed error code is returned in ZEMS-TKN-FILTER-ERROR. The row and column
locations of the error occurrences are returned in ZEMS-TKN-FAIL-REASON. (The
column is in bits <0:5>, and the row is in bits <6:15>). For descriptions of distributor
errors related to filter table use, see 1019: ZEMS-ERR-FLT-FORM on page 21-9 and
1020: ZEMS-ERR-FLT-LOAD on page 21-10.
Detailed Error Codes
Required param missing = -10
Too many subsystems = -11
Open problem = -12
Editreadinit problem = -13
Editread problem = -14
PASS or FAIL missing = -15
Invalid SSID = -16
Unknown SSID = -17
Invalid event number = -18
Invalid format for range = -19
Too many event numbers = -20
Table overflow = -21
Duplicate owner = -22
Duplicate subsystem = -23
Invalid passval = -24
Passval not allowed = -25
Invalid column position = -26
Wildcard placement error = -27
Subsystem entry required = -28
Owner entry required = -29
Event entry required = -30
Invalid owner = -31
No filter table entry = -32
Invalid start time = -40
Invalid stop time = -41
Invalid user ID = -42
Invalid standard type = -43
Invalid cpu number = -44
Invalid pin number = -45
Invalid process ID = -46
Invalid standard type = -47
Invalid user defined type = -48
Invalid emphasis = -49
Invalid keyword = -50
Duplicate keyword = -51
Event type incompatibility = -52
Invalid burst parameter N = -53
Invalid burst parameter T1 = -54
Invalid burst parameter T2 = -55
Invalid burst parameter T3 = -56
Invalid burst parameter S = -57
Invalid burst parameter L = -58