Procedure Calls for Standard Events
EMS Manual426909-005
11-5
Condition Code Settings
If not present, the default is ZSPI-VAL-FALSE.
Manager name input
STRING .EXT:ref:*
if present, is the name of the manager process of the object that received the
transient fault.
If present and Manager name length is not zero, Manager name is added to
the event buffer. Otherwise, Manager name is not added to the event buffer.
Manager name length input
INT:value
if present, is the length, in bytes, of the Manager name.
If not present or the value is zero, Manager name is not added to the event buffer.
Job ID input
INT:value
if present, is the job ID (for use by the NetBatch facility) that associates with the
object experiencing the transient fault.
If Job ID is zero or not present, see Considerations on page 11-6.
Condition Code Settings
The condition code has no meaning following a call to