EMS Manual

Procedure Calls for Standard Events
EMS Manual426909-005
11-16
Condition Code Settings
Job ID input
INT:value
if present, is the job ID (for use by the NetBatch facility) that associates with the
object that became available.
If Job ID is zero or not present, see Considerations on page 11-16.
Condition Code Settings
The condition code has no meaning following a call to EMS_OBJ_AVAIL_EVT_BLD_.
Considerations
To generate the common tokens:
SSID: from SSID.
Event subject token code: from Subject token ID
Event subject value: from Subject value
Event subject SSID: from Subject SSID. Conditional.
Manager Name (zems-tkn-name-manager): from Manager
name.Conditional.
Event Number (zems-tkn-eventnumber): from Event number
Standard Content type (zems-tkn-content-standard):
ZEMS-VAL-OBJECT-AVAILABLE.
User Content type (zems-tkn-content-user): ZEMS-VAL-NULL.
Critical Indicator (zems-tkn-emphasis): from Critical
indicator.
Suppress display (zems-tkn-suppress-display):
ZSPI-VAL-FALSE.
Batch job ID (zems-tkn-batchjob-id): from Job ID.
Conditional.
The values for User Content type and Suppress display can be
changed by calling EMSADDTOKENS.
To generate the additional tokens:
Current state (zems-tkn-state-current): from Current state.
Previous state (zems-tkn-state-previous): from Previous
state.
Change reason (zems-tkn-change-reason): from Change reason.