EMS_UTCB_INIT_
Usage Threshold Control Block input, output
INT .EXT:ref:20
is the control block used by subsequent calls to
EMS_USAGE_THRESHOLD_CHK_ and
EMS_USAGE_THRESHOLD_EVT_BLD_.
Configured High Level input
FLOAT:value
is the configured high usage level used in calculating whether a Usage Threshold
event should be generated.
Configured Low Level input
FLOAT:value
is the configured low usage level used in calculating whether a Usage Threshold
event should be generated.
Utilization level unit input
INT: value
is the utilization level unit used. Standard values are:
ZEMS-VAL-UTIL-UNIT-PERCENT Unit in %
ZEMS-VAL-UTIL-UNIT-USEC Unit in micro-seconds
ZEMS-VAL-UTIL-UNIT-MSEC Unit in milliseconds
ZEMS-VAL-UTIL-UNIT-HSEC Unit in hundredth-of-seconds
ZEMS-VAL-UTIL-UNIT-TSEC Unit in tenth-of-seconds
ZEMS-VAL-UTIL-UNIT-SEC Unit in seconds
ZEMS-VAL-UTIL-UNIT-MIN Unit in minutes
ZEMS-VAL-UTIL-UNIT-HOUR Unit in hours
ZEMS-VAL-UTIL-UNIT-BPS Unit in bytes/sec
ZEMS-VAL-UTIL-UNIT-KBPS Unit in kilobytes/sec
ZEMS-VAL-UTIL-UNIT-MBPS Unit in megabytes/sec
ZEMS-VAL-UTIL-UNIT-GBPS Unit in gigabytes/sec
ZEMS-VAL-UTIL-UNIT-TBPS Unit in terabytes/sec
ZEMS-VAL-UTIL-UNIT-BYTES Unit in bytes
ZEMS-VAL-UTIL-UNIT-KBYTES Unit in kilobytes
ZEMS-VAL-UTIL-UNIT-MBYTES Unit in megabytes
ZEMS-VAL-UTIL-UNIT-GBYTES Unit in gigabytes
ZEMS-VAL-UTIL-UNIT-TBYTES Unit in terabytes
ZEMS-VAL-UTIL-UNIT-COUNTER Unit in count
Condition Code Settings
The condition code has no meaning following a call to EMS_UTCB_INIT_.