EMS Manual
Procedure Calls for Standard Events
EMS Manual—426909-005
11-39
EMS_USAGE_THRESHOLD_EVT_BLD_
Condition Code Settings
The condition code has no meaning following a call to
EMS_USAGE_THRESHOLD_EVT_BLD_.
Considerations
To generate the common tokens:
SSID: from SSID.
Event subject token code: from Subject token ID
Event subject value: from Subject value
Event subject SSID: from Subject SSID. Conditional.
Manager Name (zems-tkn-name-manager): from Manager
name.Conditional.
Event Number (zems-tkn-eventnumber): from Event number
Standard Content type (zems-tkn-content-standard):
ZEMS-VAL-USAGE-THRESHOLD.
User Content type (zems-tkn-content-user): ZEMS-VAL-NULL.
Critical Indicator (zems-tkn-emphasis): from Critical
indicator.
Suppress display (zems-tkn-suppress-display):
ZSPI-VAL-FALSE.
Batch job ID (zems-tkn-batchjob-id): from Job ID.
Conditional.
The values for User Content type and Suppress display can be
changed by calling EMSADDTOKENS.
To generate the additional tokens:
Current utilization level (zems-tkn-util-level-curr): from
Usage Threshold Control Block.
Previous utilization level (zems-tkn-util-level-prev): from
Usage Threshold Control Block. This token is not added if
the event is the first time being reported.
Previous timestamp (zems-tkn-util-time-prev): from Usage
Threshold Control Block. This token is not added if the
event is the first time being reported.
Configured High level (zems-tkn-util-config-hi): from Usage
Threshold Control Block.
Configured Low level (zems-tkn-util-config-low): from Usage
Threshold Control Block.