EMSCINFO—Collector Information Utility
EMSCINFO—Collector Information Utility
The EMSCINFO utility returns status information about a primary or alternate collector.
For a description of the command message that provides the same information, see
STATUS Command (ZEMS-CMD-STATUS) on page 19-53.
To change these attributes, see EMSCCTRL—Control Collector Utility on page 13-9.
When the DETAIL parameter option is present in the EMSCINFO command syntax, a
number of BDS and PLF parameters and counters can be viewed. The DETAIL
parameter option lets the user view this additional information while maintaining
manageable screen size.
EMSCINFO Display Examples (No DETAIL Parameter)
Example 13-1 shows the primary collector status display produced by EMSCINFO in
response to the command “EMSCINFO $0,” without the DETAIL option specified.
Definition of Terms on page 13-19, describes the terms in Example 13-1.
EMSCINFO [<collector name>] [, DETAIL]
Example 13-1. EMSCINFO Primary Collector Display (No DETAIL Parameter)
EMSCINFO - T9631D31 - (03APR95)
Collector = $0, Priority = 201
Primary CPU = 1, Backup CPU = 0
Disk Logging Active
Current Log File = $SYSTEM.ZLOG06.ZZEV0045
Current Record = %000005.050003
Default Log File = $SYSTEM.ZLOG06.ZZEV0045
Primary Extent = 20, Secondary Extent = 100
ROTATEFILES = ON, MAXFILE = 4
REFRESH = ON, BUFFERED = ON
SECURITY = NUUU, BLOCKING = ON
Events Received = 707516, Events Logged = 705697
Events Discarded = 1909
OPENS Received = 241, CLOSES Received = 233
FILE Switches = 45, Unrcv Disk Errors = 0
Invalid Events = 0, Buffer Failures = 1909
SUPPRESS = OFF, FILTER = ON
Compatibility Distributor ($Z0)
Printing Mode = CRITICAL-ONLY
Primary CPU = 0, Backup CPU = 1
Console Name = $0