EMS Manual

EMS Programs
EMS Manual426909-005
13-26
EMSCINFO Display Examples (With DETAIL
Option)
The EMSCINFO detail display example in Example 13-4 provides this information
about burst detection and suppression (BDS):
The SUPPRESS function is set to ON for the primary collector through the
SUPPRESS keyword of the EMSCCTRL command (SUPPRESS ON). Therefore,
burst detection and suppression for the primary collector was enabled using the
SUPPRESS ON command.
The last-recorded BDS configuration values and their meanings are listed.
The current number of event bursts (two) is shown.
The event number and subsystem ID for each reported event burst is shown.
Information about the first subject in each burst event is provided (token code,
length in bytes, subsystem ID, and subject value).
The number of events discarded with each event burst is shown.
The EMSCINFO detail display example in Example 13-4 provides this information
about pre-log filtration (PLF):
The FILTER function is set to ON for the primary collector using the FILTER
keyword of the EMSCCTRL command (FILTER ON). Therefore, pre-log filtration in
the primary collector is currently enabled.
The number of filters present is 2.
The first filter’s file name and filter type (COMPILED) are shown.
The second filter’s file name and filter type (TABLE, PASS) are shown.
Example 13-5 is another example of the EMSCINFO display for a primary collector
when the DETAIL option is included in the EMSCINFO command line. It shows both
the primary collector’s current BDS configuration data information and the PLF data
information. In this example, SUPPRESS is set to OFF and FILTER is set to ON. In
this example, a burst filter is present.