EMS Manual

EMS Programs
EMS Manual426909-005
13-47
Startup Error Messages
Recovery. Specify a valid textout wait time.
Cause. A necessary keyword is not supported.
Effect. The distributor fails to start up.
Recovery. Specify one of the provided keywords.
Cause. The specified LOGFILE and COLLECTOR cannot coexist, because LOGFILE
and COLLECTOR are mutually exclusive keywords.
Effect. The distributor fails to start up.
Recovery. Do not specify LOGFILE and COLLECTOR at the same time.
Cause. A log problem has occurred with the specified OPEN or READ procedure.
Effect. The distributor fails to start up.
Recovery. Check the log-file and determine the cause of the OPEN or READ error.
Cause. A backup CPU is specified, but the process is not named.
Effect. The distributor fails to start up.
Recovery. Either specify the NAME parameter in the TACL RUN statement, or do not
specify a backup CPU.
Cause. A distributor type (either C[ONSUMER], F[ORWARDING], or P[RINTING]
must be specified, but was not.
Effect. The distributor fails to start up.
Recovery. Specify the distributor type.
Keyword not found
Select from: TYPE, BACKUP, COLLECTOR, FILTER, LOGFILE,
TARGET, TEXTOUT, TIME, STOP, DELAY, SBUF, AUTOSTOP, DUMP,
WAIT, INDENT, GMT, RETRY
LOGFILE and COLLECTOR cannot coexist
Log problem proc-name error x on file-name
[ COLLECTOR collector-name ]
Must be named to run in NonStop mode
Must specify distributor type: C[ONSUMER], F[ORWARDING], or
P[RINTING]
Must specify ON or OFF