EMS Manual
EMS Programs
EMS Manual—426909-005
13-48
Startup Error Messages
Cause. An incorrect value is specified for the SBUF, DUMP, or GMT option.
Effect. The distributor fails to start up.
Recovery. Specify ON or OFF for the necessary options.
Cause. A required name or value is missing in the command.
Effect. The distributor fails to start up.
Recovery. Check that all required names and values are present in your command.
Cause. A parenthesis needs to be cancelled by another, as in “(xyz,” or “xyz).”
Effect. The distributor fails to start up.
Recovery. Check that all parentheses are used in pairs.
Cause. None of the TEXTOUT destinations specified in the TEXTOUT list can be
opened; that is, events cannot be printed anywhere.
Effect. The distributor fails to start up.
Recovery. Check the specified TEXTOUT destinations to determine why they could
not be opened. Check that they are referred to correctly in the command.
Cause. The distributor attempted to fetch an event, but no source collector was
specified.
Effect. The distributor does not start up.
Recovery. Check that a source collector is specified.
Cause. The position time for the specified log file is too early.
Effect. The distributor displays events from the earliest log available.
Name or value missing
No matching parenthesis
None of the specified TEXTOUT can be opened
No source collector open
Position time too early log file-name
[ collector collector-name ]
Continuing...