EMS Manual
EMS Programs
EMS Manual—426909-005
13-49
Startup Error Messages
Recovery. None needed.
Cause. The position time for the specified log file is too late.
Effect. The distributor waits for the next event.
Recovery. None needed.
Cause. A collector was specified as an event source that is a pre-C00 version
collector.
Effect. The distributor fails to start up.
Recovery. Use a post-C00 collector as an event source.
Cause. A D-series distributor started without a name, and the RUNNAMED flag was
reset with the finder.
Effect. The distributor fails to start up.
Recovery. Set the RUNNAMED flag with the finder to make NonStop Kernel assign a
processname, or specify the name parameter in the TACL RUN command.
Cause. The RETRY option is specified in log file mode, which is not allowed.
Effect. The distributor fails to start up.
Recovery. Specify a collector in the startup line.
Cause. The STOP parameter is specified for a consumer distributor, which is not
allowed.
Effect. The distributor fails to start up.
Recovery. Specify a printing or forwarding distributor.
Cause. The STOP time cannot be smaller than or equal to the TIME parameter.
Position time too late log file-name
[ collector collector-name ]
Continuing...
Pre-C00 collector not supported
Process must be named
RETRY only allowed in collector mode
STOP time not allowed for consumer distributor
STOP time smaller/equal start time