EMS Manual
Distributor Event Messages
EMS Manual—426909-005
18-14
1000: ZEMS-EVT-LOG-ACCESS
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens described in Section 14, EMS Definitions.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-LOGNAME (nonshared)
is the file name of a log file. Here it is the log file in use when the event
occurred.
ZSPI-TKN-PROC-ERR (nonshared)
specifies a procedure associated with the event. Here EMS assigns one of these
values:
ZEMS-VAL-ZFILOPEN 22
ZEMS-VAL-ZFILPOSITION 23
ZEMS-VAL-ZFILREAD 24
The extensible structured token ZEMS-MAP-STATUS-DIST and tokens ZEMS-TKN-
ZFILERR, -COLNAME-ENUM, and COLNAME are described in Token and Data Type
Definitions on page 18-3.
Cause. The distributor is using the log files of a collector as its source of event
messages. While proceeding from one file to the next, the distributor finds it cannot
access a log file. A security violation might have occurred, or a log file might have been
purged.
Effect. The distributor closes the old log file and tries to access the file that follows the
missing log file in the file series. If no other log file exists, the distributor disconnects
the collector. See also 1019: ZEMS-EVT-COL-DISCONNECT
on page 18-49.
Recovery. If a security violation occurred or a log file was purged, correct the problem.
Otherwise, contact your service provider. After you make the log file available, rerun
any applications that depend on it.