EMS Manual
Distributor Event Messages
EMS Manual—426909-005
18-16
1001: ZEMS-EVT-COLL-ACCESS
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens described in Section 14, EMS Definitions.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-COLNAME (nonshared)
is the name of a collector. Here, it is a collector that the distributor cannot
access.
ZEMS-TKN-COLNAME-ENUM (nonshared)
is described in Token and Data Type Definitions on page 18-3.
ZSPI-TKN-PROC-ERR (nonshared)
specifies a procedure associated with the event. Here, EMS assigns one of these
values:
ZEMS-VAL-ZFILOPEN 22
ZEMS-VAL-ZFILWRITEREAD 26
The extensible structured token ZEMS-MAP-STATUS-DIST and the token
ZEMS-TKN-ZFILERR are described in Token and Data Type Definitions on
page 18-3.
Cause. The distributor tries to access a collector—often to get an event message from
one of the collector’s log files—and finds it cannot do so.
Effect. The distributor disconnects the failing collector but continues to run. (An
application can direct the distributor to reconnect the same collector after the problem
has been corrected.)
Recovery. If this error was caused by a security violation, restart the collector, then
reconnect it. Otherwise, contact your service provider.