EMS Manual

Distributor Event Messages
EMS Manual426909-005
18-28
1008: ZEMS-EVT-DEVTYPE
ZEMS-TKN-EMPHASIS (shared)
is a standard EMS token; for more information, see Section 14, EMS Definitions.
Its value here is FALSE.
ZEMS-TKN-CONSOLE-PRINT (shared)
is a standard EMS token; for more information, see Section 14, EMS Definitions.
Its value here is TRUE.
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens described in Section 14, EMS Definitions
.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-FAILFILENAME (nonshared)
is the file name of a bad file. Here it is the name of a log file or collector that the
distributor could not access.
The extensible structured token ZEMS-MAP-STATUS-DIST and the token ZEMS-TKN-
DEVTYPE-ENUM are described in Token and Data Type Definitions
on page 18-3.
Conditional Tokens
The tokens ZEMS-TKN-COLNAME-ENUM and -COLNAME are present when the
event-message source is a collector and are described in Token and Data Type
Definitions on page 18-3.
The tokens ZEMS-TKN-FILECODE, -BLOCKLENGTH, and -DEVICE-TYPE are
present if a bad file code, bad block length, or bad device type is responsible for the
access problems. For more information, see Token and Data Type Definitions on
page 18-3.
Cause. The distributor cannot access an event message log file or collector because
the file code, device type, or block length is incorrect. Something is wrong with the
specified source of event messages; for example, you might have specified the wrong
name for a log file or for a collector process.
Effect. The associated collector is disconnected, but the distributor continues to run.
Recovery. Make sure you specified a correct EMS event-log file name. If you
specified a correct name, contact your HP representative. An application can direct the
distributor to reconnect the same collector after the problem is corrected.