EMS Manual
Distributor Event Messages
EMS Manual—426909-005
18-43
1016: ZEMS-EVT-CHECKPOINT-FAILED
ZEMS-TKN-CONSOLE-PRINT (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Its value here is TRUE.
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens described in Section 14, EMS Definitions.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-DIST-NAME (nonshared)
is the name of the distributor process.
ZEMS-TKN-ZFILERR (nonshared)
is described in Token and Data Type Definitions on page 18-3.
ZSPI-TKN-PROC-ERR (nonshared)
specifies a procedure associated with the event. Here EMS assigns the value of
ZEMS-VAL-CHECKPOINT to 37.
Cause. The distributor’s backup process received an I/O error during a checkpoint
operation.
Effect. The distributor backup process is stopped, and an attempt is made to create a
new backup after a 30-second delay. Resource allocation failures (errors 30 through
37) might indicate that the primary and/or backup CPU is overloaded.
Recovery. For errors 30 through 37, free system resources. If this does not correct the
problem, or results in a different error, contact your service provider.