1019: ZEMS-EVT-COL-DISCONNECT
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-COLNAME (nonshared)
is the name of a collector. Here, it is the collector that the distributor is
disconnecting.
The extensible structured token ZEMS-MAP-STATUS-DIST and the token ZEMS-TKN-
COLNAME-ENUM are described in Token and Data Type Definitions on page 18-3.
Cause. The distributor is using collector log files as a source of event messages.
Because of a hardware, software, or operations failure, the distributor cannot access
any of the collector’s log files.
Effect. The distributor disconnects the specified collector but continues running. An
application can direct the distributor to reconnect the original collector after the problem
is corrected.
Recovery. Make sure the line to the remote collector is up. For recovery information,
see the description of the accompanying message. If you cannot solve the problem,
contact your service provider.