1020: ZEMS-EVT-STARTUP-FAILED
ZEMS-VAL-MONITOR-COMM
ZEMS-VAL-LIBRARY-FILE
ZEMS-VAL-PROGRAM-FILE
ZEMS-VAL-NO-EXT-SEGMENT
ZEMS-VAL-EXT-SEGMENT-SWAP
ZEMS-VAL-BAD-HOMETERM
ZEMS-TKN-STARTUP-LOGTIME (type: ZSPI-TYP-TIMESTAMP; nonshared)
is the log time of the event that triggered the startup.
For a description of the extensible structured token ZEMS-MAP-STATUS-DIST, see
Token and Data Type Definitions on page 18-3.
Conditional Token
The token ZEMS-TKN-ZFILERR is described in Token and Data Type Definitions on
page 18-3.
Cause. The distributor cannot create a destination process due to a
PROCESS_CREATE_ error. One retry was attempted and failed. This event is similar
to the ZEMS-EVT-CREATEBACKUP-FAILED event. This event message is issued only
if the initial attempt to create the process fails; unsuccessful retries resulting from
subsequent event triggers are not reported.
Effect. If the startup eventually succeeds, another message (ZEMS-EVT-STARTUP-
OK) is generated.
Recovery. The action to be taken depends on the most significant byte of the
PROCESS_CREATE_ error:
For other errors, contact your service provider.
MSB = 2.
The specified CPU cannot run any additional processes. Change the routing
profile for this destination.
MSB = 3.
Check the distributor's code file.
MSB = 4.
Change the CPU in the routing profile as in (2).
MSB = 5.
Most likely the disc volume selected for the destination's SWAPVOL is out of
space. Purge unneeded files from the volume or change the startup
message in the destination's profile to specify a different volume.
MSB =
10.
Check that the CPU specified for the destination is one that exists on your
system; if not, change the CPU as in (2). Otherwise, check the CPU.