EMS Manual
Collector Commands and Responses
EMS Manual—426909-005
19-5
Common Command Tokens for ZCOM- Commands
These collector commands do not accommodate pre-D00 tokens that do not support a
high PIN or a string file name. Such tokens generate a ZCOM-ERR-TKN-CODE-INV
error.
Common Command Tokens for ZCOM- Commands
Table 19-3 summarizes the common command tokens for the extended SPI-compliant
collector commands, their ZSPI token type, and special usage considerations.
Usage Considerations
SSINIT signifies that the value for this token must be supplied in the call to SSINIT
to create the SPI command.
Note. These commands are sent directly from the requestor to the EMS collector. An SCP
process is not used.
Table 19-3. Common Command Tokens for ZCOM-Collector Commands
Command Token Token Type Usage
ZSPI-TKN-COMMAND ZSPI-TYP-ENUM
SSINIT
ZSPI-TKN-OBJECT-TYPE ZSPI-TYP-ENUM
SSINIT
ZSPI-TKN-SSID ZSPI-TYP-SSID
SSINIT
ZSPI-TKN-MAXRESP ZSPI-TYP-INT
Basic SPI
ZCOM-TKN-XMGR ZSPI-TYP-STRING
Optional
ZCOM-TKN-REQID-PAID ZSPI-TYP-INT
Optional
ZCOM-TKN-REQID-PHANDLE ZSPI-TYP-PHANDLE
Optional
ZCOM-TKN-REQID-PPROGXFILE ZSPI-TYP-STRING
Optional
ZCOM-TKN-REQID-PSTRING ZSPI-TYP-STRING
Optional
ZCOM-TKN-OBJNAME ZSPI-TYP-STRING
Required
ZCOM-TKN-SUB ZSPI-TYP-ENUM
Optional
ZCOM-TKN-SEL-SUMSTATE ZSPI-TYP-INT-PAIR
Ignored
ZCOM-TKN-CMD-POWER ZSPI-TYP-ENUM
Ignored
ZCOM-TKN-CMD-TIMEOUT ZSPI-TYP-TIMESTAMP
Ignored
ZSPI-TKN-RESPONSE-TYPE ZSPI-TYP-ENUM
Ignored
ZSPI-TKN-ALLOW-TYPE ZSPI-TYP-ALLOW-TYPE
Ignored
ZSPI-TKN-ALLOW ZSPI-TYP-ENUM
Ignored
ZSPI-TKN-COMMENT ZSPI-TYP-STRING
Ignored
ZSPI-TKN-CONTEXT ZSPI-TYP-BYTESTRING
Basic SPI