EMS Manual
Collector Commands and Responses
EMS Manual—426909-005
19-11
Common Response Tokens for ZCOM- Commands
zbds-flags
is a field that contains several bit fields that further describe the particular BDS
configuration. These bits fields are:
zbds-f.enabled
is set to 1 if BDS is enabled and set to 0 if BDS is disabled.
zbds-f.tmds
in the EMS alternate collector, this bit is set to 1 if it is running in TMDS
mode; otherwise, it is set to 0. The EMS primary collector always sets this
bit to 0.
zbds-f.use-subj
is set to 1 if the subject token code is used to determine similar events; this
bit is set to 0 if the subject token code is ignored in determining similar
events.
zbds-f.process-type
indicates the process type of the process performing BDS. The alternate
collector stores ZEMS-SUBJ-ACOLL in this field. The primary collector
stores ZEMS-SUBJ-PCOLL.
zbds-num-events
identifies the number of events that constitute an event burst. This field
provides the same information as the N parameter in the EMSACOLL and
EMSCCTRL RUN commands.
zbds-interval-start
the occurrence of N events during this time interval (in seconds) constitutes the
start of an event burst. This field provides the same information as the T1
parameter in the EMSACOLL and EMSCCTRL RUN commands.
zbds-interval-end
the occurrence of no events during this time interval (in seconds) constitutes
the end of an event burst. This field provides the same information as the T2
parameter in EMSACOLL and EMSCCTRL.
zbds-interval-chk-end
indicates the maximum interval (in seconds) in which the EMS collector checks
for a burst end condition. In other words, the collector waits no longer than this
interval between burst end checks. This is the same as the T3 parameter in
EMSACOLL and EMSCCTRL.