EMS Manual

Collector Commands and Responses
EMS Manual426909-005
19-28
Common ZSPI-TKN-RETCODE Values
ZSPI-TKN-SERVER-VERSION (type uint)
is the subsystem version number of the EMS collector. It is contained in a
response buffer.
ZSPI-TKN-SSID (type ssid)
contains ZSPI-SSN-ZEMS, the subsystem ID for the Event Management Service.
It is contained in a response buffer.
Common ZSPI-TKN-RETCODE Values
Table 19-5 shows the names and numbers of ZSPI-TKN-RETCODE values returned by
a primary or alternate collector if a command message cannot be correctly interpreted.
Errors that occur in a particular command are defined with that command.
For detailed descriptions of collector error codes and related error lists, see Section 22,
Collector Errors.
Table 19-5. Command-Interpretation Errors
Name (ZEMS-ERR-) Number Description
VERSION 1001 Version not supported
INV-CMD 1002 Invalid command
INV-SSID 1003 Invalid subsystem ID (SPI buffer not owned by EMS)
INV-TKN 1004 Extra or unrecognized token
INV-VALUE 1005 Illegal token value
DUP-TKN 1006 Duplicate token code
INV-OBJECT 1008 Invalid object type
INV-OCCURS 1017 Application buffer too small for response
ZSPI 1041 SPI error while decoding command buffer or building
response buffer