EMS Manual
Collector Commands and Responses
EMS Manual—426909-005
19-34
CONTROL Command (ZEMS-CMD-CONTROL)
CONTROL Command (ZEMS-CMD-CONTROL)
The ZEMS-CMD-CONTROL command lets you programmatically manage the 
operation of the primary and alternate collectors and the compatibility distributor. You 
do this by changing the settings of one or more operational attributes for the 
appropriate process. Table 19-6 shows the attributes you can set when you use the 
CONTROL command and the EMS process controlled by each attribute.
In addition to the required token ZSPI-TKN-COMMAND, which specifies the command 
type to the SPI interface, each CONTROL command buffer must contain tokens or 
token maps that define the values of attributes to be changed. You include only the 
values of the attributes to be changed. The values of the attributes not included remain 
the same. Two fields in the ZEMS-MAP-COL-CONTROL token map control the 
enabling and disabling of BDS and PLF.
Table 19-6. Attributes Changed by the CONTROL Command
Option
Primary 
Collector
Alternate 
Collector
Compatibility
Distributor
Primary CPU x x x
Log subvolume x x
Next logfile x x
Primary extent x x
Secondary extent x x
Rotate files x x
Maxfile x x
EOF refresh x x
Write through cache x x
Protection x x
Blocking x x
BDS x x
PLF x x
Discaccessid x
Allocate x
Console out x
Textout set x
Mode set x
User set x