STATUS Command (ZEMS-CMD-STATUS)
ZEMS-MAP-COL-CDIST-STATUS
is an extensible structured token that gives you the current values of the
operational environment of $Z0 and some event-message statistics.
ZCOL-CDISTPRICPU (uint field)
is the number of the CPU in which the primary process of the compatibility
distributor is running.
ZCOL-CDISTBKUPCPU (uint field)
is the number of the CPU in which the backup process of the compatibility
distributor is running.
ZCOL-STOPCOMPATDIST (Boolean field)
is the current run state of the compatibility distributor. This field is -1 if the
compatibility distributor is stopped.
ZCOL-DISTR-ERROR (uint field)
is the current error condition of the compatibility distributor console device. This
field is 0 if no error exists.
ZCOL-OPRLOG-ERROR (uint field)
is not used starting in D20 systems.
ZCOL-CDIST-MODE (enum field)
indicates that $Z0 displays only critical events if ON, or all events if OFF.
ZCOL-CDIST-TEXTOUT (fname field)
is the destination file name for CONSOLE—the console device that the
compatibility distributor uses for text output.
ZCOL-CDIST-USER (userid field)
is the user ID that the compatibility distributor uses when forwarding event
messages to the console from a remote collector (one on another node).
ZCOL-CDIST-DEF-TEXTOUT (fname field)
is the name of the default operator console selected during system load.
ZSPI-TKN-RETCODE (type enum)
is the standard SPI return token. A zero value for this token signals the successful
execution of the command. A nonzero value signals that the command failed. For a
list of the values that can be returned in the ZSPI-TKN-RETCODE token, see
Error-Handling Notes on page 19-61.