EMS Manual

Collector Event Messages
EMS Manual426909-005
20-6
Tokenized Operator Console Messages (1–511)
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
-USERID, and -OPMSG
are all standard EMS tokens. For more information, see Section 14, EMS
Definitions.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. Event
messages 1 through 511 each have one subject token: ZEMS-TKN-XSYSPID.
ZEMS-TKN-XSYSPID
is private to HP. It contains the system number and PID of some process
associated with the event message.
Conditional Tokens
ZEMS-MAP-EXIOADDR
(D-series RVUs only) is an extensible structured token, private to HP. It is found in
some messages that include the ZEMS-TKN-OPMSG token. When present, the
ZEMS-MAP-EXIOADDR token contains the extended physical address of the I/O
device associated with the subject of the event message.
Cause. For the cause of each of these event messages, see the Operator Messages
Manual.
Effect. For the effect of each of these event messages, see the Operator Messages
Manual.
Recovery. The action recommended depends on the particular event message.
Event Notes
In its original form, a nontokenized operator message that is critical contains a BEL
character to draw the operator’s attention. In its tokenized form, the message
contains an EMPHASIS token set to TRUE (see Section 14, EMS Definitions), and
the formatted display text contains a BEL character.
The ZEMS-TKN-EVENTNUMBER token for these event messages is in the range
1 through 511.