EMS Manual
Collector Event Messages
EMS Manual—426909-005
20-10
513: ZEMS-EVT-COLD-LOAD
ZEMS-TKN-EMPHASIS (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Here, its value is TRUE.
ZEMS-TKN-CONSOLE-PRINT (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Here, its value is TRUE.
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens. For more information, see Section 14, EMS Definitions
.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token: ZEMS-TKN-COLLECTOR.
ZEMS-TKN-COLLECTOR (nonshared)
specifies the collector type. This token has the value ZEMS-SUBJ-PCOLL (or
1).
Cause. An operator has performed a system load that generated the event message.
Effect. The primary collector generates this event message when a system load is
performed and disk logging begins.
Recovery. This event message is primarily informative and is useful as a place marker
in the event log.