EMS Manual
Collector Event Messages
EMS Manual—426909-005
20-12
514: ZEMS-EVT-FILESWITCH
ZEMS-TKN-EMPHASIS (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Here, its value is TRUE.
ZEMS-TKN-CONSOLE-PRINT (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Here, its value is TRUE.
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens. For more information, see Section 14, EMS Definitions
.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token: ZEMS-TKN-COLLECTOR.
ZEMS-TKN-COLLECTOR (nonshared)
is the collector type. This token has the value ZEMS-SUBJ-PCOLL (or 1) for
the primary collector, and ZEMS-SUBJ-ACOLL (or 2) for the alternate collector.
ZEMS-TKN-LASTLOGFILE (nonshared)
is the file name of the log file in use before the switch.
ZEMS-TKN-NEWLOGFILE (nonshared)
is the file name of the log file in use after the switch.
ZEMS-TKN-LOGSWITCHREASON (nonshared)
is the reason for the file switch, shown by one of the following values:
ZEMS-VAL-OPRSWITCH
is the file switch by operator.
ZEMS-VAL-DISCACCESS
is the disk file that is not accessible.
ZEMS-VAL-FILEFULL
is the previous file filled.
ZEMS-MAP-COL-STATUS
is an extensible structured token that contains the current status of the collector;
see STATUS Command (ZEMS-CMD-STATUS)
on page 19-53.