EMS Manual

Collector Event Messages
EMS Manual426909-005
20-36
527: ZEMS-EVT-ACOL-SHUTDOWN
ZEMS-TKN-COLLECTOR (nonshared)
specifies the collector type. This token can have only one value: ZEMS-SUBJ-
ACOLL (or 2).
ZEMS-TKN-CODESEG (nonshared)
is the code segment number where the error is detected.
ZEMS-TKN-PREG (nonshared)
is the P register contents where the error is detected.
Cause. The alternate collector has encountered an internal error. This event message
should never occur. This event message is sent to the primary collector on the
alternate collector’s system. The alternate collector does not attempt to write this event
to its own logging file.
Effect. The collector stops.
Recovery. Contact your HP representative.
527: ZEMS-EVT-ACOL-SHUTDOWN
Unconditional Tokens
ZSPI-TKN-SSID
is the subsystem ID for EMS, as described in the SPI Programming Manual.
Unconditional Tokens Token Type
ZSPI-TKN-SSID ZSPI-TYP-SSID.
ZEMS-TKN-EVENTNUMBER ZSPI-TYP-INT.
ZEMS-TKN-EMPHASIS ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT ZSPI-TYP-BOOLEAN.
ZEMS-TKN-GENTIME ZSPI-TYP-TIMESTAMP.
ZEMS-TKN-LOGTIME ZSPI-TYP-TIMESTAMP.
ZEMS-TKN-CPU ZSPI-TYP-INT.
ZEMS-TKN-PROC-DESC ZSPI-TYP-STRING.
ZEMS-TKN-PIN ZSPI-TYP-INT.
ZEMS-TKN-NODENUM ZSPI-TYP-INT2.
ZEMS-TKN-USERID ZSPI-TYP-UINT.
ZEMS-TKN-SUBJECT-MARK ZSPI-TYP-SSCTL.
ZEMS-TKN-COLLECTOR ZSPI-TYP-ENUM.
Event-Message Text
EMS: COLLECTOR processname SHUTDOWN
Note: processname comes from the token ZEMS-TKN-PROC-DESC.