EMS Manual

Collector Event Messages
EMS Manual426909-005
20-41
529: ZEMS-EVT-ACOL-CHECKOPEN-FAILED
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has two subject tokens:
ZEMS-TKN-COLLECTOR (nonshared)
specifies the collector type. This token can have only one value: ZEMS-SUBJ-
ACOLL (or 2).
ZEMS-TKN-FAILFILENAME (nonshared)
is the name of the file that could not be opened by the backup alternate
collector.
ZEMS-TKN-ZFILERR (nonshared)
is the error code associated with an event. For an explanation of this error code,
see the Operator Messages Manual.
Cause. The alternate collector has determined that its backup process is
malfunctioning because it cannot open a file previously opened by the primary process.
Effect. The collector stops its backup process and attempts to create a new backup
after a 30-second delay.
Recovery. For file system errors 30 through 37, wait and try again. If the error occurs
again, increase system resources. If this does not correct the problem, or if it results in
a different error, contact your service provider.