EMS Manual

Collector Event Messages
EMS Manual426909-005
20-47
532: ZEMS-EVT-ACOL-BACKUP-CREATED
ZEMS-TKN-EMPHASIS (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Here, its value is FALSE.
ZEMS-TKN-CONSOLE-PRINT (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
Here, its value is TRUE.
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens. For more information, see Section 14, EMS Definitions
.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has two subject tokens:
ZEMS-TKN-COLLECTOR (nonshared)
specifies the collector type. This token can have only one value: ZEMS-SUBJ-
ACOLL (or 2).
ZEMS-TKN-PROGRAMFILE (nonshared)
is the name of the program file. Here, it is the program file for the alternate
collector.
ZEMS-TKN-NEWPROCESS-CPU (nonshared)
is the CPU number specified in the PROCESS_CREATE_ procedure call.
ZEMS-TKN-NEWPROCESS-PRIORITY (nonshared)
is the alternate collector priority.
Cause. The alternate collector’s primary process successfully started a new backup
process.
Effect. A new backup process is started and begins to function normally.
Recovery. This event message is for information only. No corrective action is
necessary.