535: ZEMS-EVT-ACOL-CHECKPOINT-ERR
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-COLLECTOR (nonshared)
specifies the collector type. This token can have only one value: ZEMS-SUBJ-
ACOLL (or 2).
Cause. The alternate collector’s backup process received an I/O error during a
checkpoint operation.
Effect. The alternate collector stops its backup process and attempts to create a new
backup after a 30-second delay. Resource allocation failures (file system errors 30
through 37) might indicate that the primary or backup CPU is overloaded.
Recovery. For file system errors 30 through 37, wait and try again. If the error occurs
again, free the system resources. If this does not correct the problem, or results in a
different error, contact your service provider.