EMS Manual
Collector Event Messages
EMS Manual—426909-005
20-64
540: ZEMS-EVT-PLF-ERROR
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-COLLECTOR
is the EMS process type (value 1 for the primary collector and value 2 for an
alternate collector).
ZEMS-TKN-FILTER-ERROR
is the filter evaluation error. The actual error code denotes a specific problem in
interpreting the filter (most likely a compiled filter). This error might indicate an
EMF filter compiler problem. For additional support, contact your service provider.
ZEMS-TKN-FILTERNAME
is the name of the compiled filter or filter table in which the error occurred. This is
not the filter’s file name.
ZEMS-TKN-EVT-EVTNUM
is the event number from the event where the error occurred.
ZEMS-TKN-EVT-GENTIME
is the generation timestamp from the event where the error occurred.
Text Values
filter-error
is from ZEMS-TKN-FILTER-ERROR
filtername
is from ZEMS-TKN-FILTERNAME
eventno
is from ZEMS-TKN-EVT-EVTNUM
gentime
is from ZEMS-TKN-EVT-GENTIME
proc-desc
is from ZEMS-TKN-BURST-PROC-DESC
Cause. A filter evaluation error occurred when a filter was applied to a specific event.