EMS Manual
Collector Event Messages
EMS Manual—426909-005
20-66
541: ZEMS-EVT-PLF-RELOAD-ERROR
ZEMS-TKN-CONSOLE-PRINT (shared)
is a standard EMS token. For more information, see Section 14, EMS Definitions.
ZEMS-TKN-GENTIME, -LOGTIME, -CPU, -PROC-DESC, -PIN, -NODENUM,
and -USERID
are standard EMS tokens. For more information, see Section 14, EMS Definitions.
ZEMS-TKN-SUBJECT-MARK (shared)
is the standard EMS token that immediately precedes each subject token. This
event message has one subject token:
ZEMS-TKN-COLLECTOR (nonshared)
specifies the collector type. This token has one of two values: ZEMS-SUBJ-
PCOLL (or 1) for the primary collector or ZEMS-SUBJ-ACOLL (or 2) for the
alternate collector.
ZEMS-TKN-FILTERNAME (nonshared)
is the name of the compiled filter or filter table where the error occurred.
Text Values
filtername
is the name of the filter that could not be added.
collectorname
comes from ZEMS-TKN-PROC-DESC.
Cause. The event is generated when:
At least one filter is loaded into the alternate collector.
The filter file (filter object for burst filters or filter tables) is deleted.
The primary CPU goes down.
The backup process is stopped.
The backup CPU goes down and is reloaded.
If the backup becomes the primary and attempts to reload the deleted filter file, it
does not find it, and the message is displayed.
Effect. None.
Recovery. If you want to filter the events using the deleted filter, add the filter to the
alternate collector.