EMS Manual
Distributor Errors
EMS Manual—426909-005
21-5
503: ZEMS-WRN-TOO-LATE
Effect. The distributor starts event retrieval with the first event in the oldest log in the
log chain attached to a collector.
Recovery. Ignore this warning, or specify a time that falls within the range of the log
chain.
503: ZEMS-WRN-TOO-LATE
Cause. A log file position command was issued, but the time specified is later than the
last event in the most recent log.
Effect. The distributor waits for the next event to arrive, switching to event monitoring
mode. If the event source is a log file, an end-of-file error is reported.
Recovery. Ignore this warning, or specify a time that falls within the range of the log
chain.
504: ZEMS-WRN-STARTUP-OK
ZSPI-TKN-PROC-ERR
can have the value:
ZEMS-VAL-NEWPROCESS 36
Cause. A routing distributor attempted to launch an application and failed. After some
retries, the process creation succeeds.
Effect. Routing of event messages can proceed.
Recovery. None.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-COLNAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-LOGNAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-PROGRAMFILE token-type ZSPI-TYP-FNAME
ZEMS-TKN-STARTUP-LOGTIME token-type ZSPI-TYP-TIMESTAMP
ZEMS-TKN-NEWPROCESS-ERROR token-type ZSPI-TYP-ENUM
ZEMS-TKN-NEWPROCESS-CPU token-type ZSPI-TYP-ENUM
ZEMS-TKN-NEWPROCESS-PRIORITY token-type ZSPI-TYP-ENUM
ZEMS-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL