EMS Manual

Distributor Errors
EMS Manual426909-005
21-9
1016: ZEMS-ERR-INV-HEADERTYPE
Recovery. Make sure you provide all tokens required in the specified command.
1016: ZEMS-ERR-INV-HEADERTYPE
Cause. The distributor received a command message with an invalid header type.
Effect. The command is not executed.
Recovery. Use a valid header type in the command.
1018: ZEMS-ERR-COLL-ACCESS
ZSPI-TKN-PROC-ERR
can have the values:
ZEMS-VAL-ZFILOPEN 22
ZEMS-VAL-ZFILWRITEREAD 26
Cause. The distributor tries to access a collector—often to get an event message from
one of the collectors log files—and finds it cannot.
Effect. The distributor disconnects the failing collector but continues to run. An
application can direct the distributor to reconnect the same collector after the problem
is corrected. Automated source recovery is available.
Recovery. If this error was caused by a security violation, restart the collector, then
reconnect it. Otherwise, contact your service provider.
1019: ZEMS-ERR-FLT-FORM
ZEMS-TKN-FILTER-ERROR
can have the values:
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-COMMAND token-type ZSPI-TYP-ENUM
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-FILTER-ERROR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL