EMS Manual

Distributor Errors
EMS Manual426909-005
21-10
1020: ZEMS-ERR-FLT-LOAD
-1 Filter too big to fit into supplied buffer.
-2 Filter format invalid.
-3 Version incompatibility.
Cause. The distributor received a command message for processing a filter that is not
in the expected format. Either the filter is too big to fit in the supplied buffer, the filter
format is invalid, or a version incompatibility was detected. The filter possibly was
compiled with a version newer than the version supported by the distributor.
Effect. The filter is not added. If the specified filter is a burst filter or filter table edit file,
it cannot be converted to an object form.
Recovery. Correct the filter source, or use an appropriate compiler.
1020: ZEMS-ERR-FLT-LOAD
ZSPI-TKN-PROC-ERR
can have the values:
ZEMS-VAL-ZFILOPEN 22
ZEMS-VAL-ZFILREAD 24
Cause. The distributor could not load the filter because an I/O problem occurred, an
incorrect file name was given, or the file was not the correct type (845 for filter objects,
101 for filter table source files).
Effect. The filter is not added.
Recovery. Specify a correct name, then generate a correct filter file.
1022: ZEMS-ERR-REQ-PARAM
Cause. One or more required filter parameters are missing. Either a filter was added
that requires parameters, but no (or insufficient) parameters were submitted; or a filter
was altered, but not all required parameters were submitted.
Effect. The filter is not added, or the submitted set or parameters is not applied.
Recovery. Provide all required parameters.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL