EMS Manual
Distributor Errors
EMS Manual—426909-005
21-12
1027: ZEMS-ERR-COLL-NOT-FOUND
1027: ZEMS-ERR-COLL-NOT-FOUND
ZSPI-TKN-PARM-ERR
gives the token code and index (but not the value) of the ZEMS-TKN-
DISCONNECT-SRC-COLL token, which caused the error. The distributor includes
ZEMS-TKN-DISCONNECT-SRC-COLL (value included) to provide the collector
name.
Cause. The collector is not associated with the distributor and cannot be
disconnected.
Effect. No collector connections are altered.
Recovery. Make sure you specify a collector associated with the specified distributor.
1031: ZEMS-ERR-LOG-ACCESS
ZSPI-TKN-PROC-ERR
ZEMS-VAL-ZFILOPEN 22
ZEMS-VAL-ZFILPOSITION 23
ZEMS-VAL-ZFILREAD 24
Cause. The distributor is using a collector’s log files as its event message source.
While proceeding from one file to the next, the distributor cannot access a log file.
Either a security violation occurred, or a log file was purged.
Effect. The distributor closes the old log file and tries to access the log file that follows
the missing log file in the file series. If no other log file exists, the distributor
disconnects the collector and generates event ZEMS-EVT-COLLECTOR-
DISCONNECT.
Recovery. If a security violation occurred or a log file was purged, correct the problem.
Otherwise, contact your service provider. When the log file is available again, rerun any
applications that depend on it.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZSPI-TKN-PARM-ERR token-type ZSPI-DDL-PARM-ERR
ZEMS-DISCONNECT-SRC-COLL token-type ZSPI-TYP-FNAME
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST
ZEMS-TKN-ZFILERR token-type ZSPI-TYP-UINT
ZEMS-TKN-FAILFILENAME token-type ZSPI-TYP-FNAME
ZEMS-TKN-COLNAME-ENUM token-type ZSPI-TYP-ENUM
ZEMS-TKN-COLNAME token-type ZSPI-TYP-FNAME
ZSPI-TKN-PROC-ERR token-type ZSPI-TYP-ENUM
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL